A STUDY OF ANTI-PROTRUDING PROPERTIES OF DURA AND ITS SUBSTITUFES
ding Zurong(Department of Engineering Mechanics, Shanghai Jiaotong University, Shanghai 200030)
song Donglei,Zhou Liangfu(Department of Neurosurgery, Shanghai Huashan Hospital, Shanghai 200040)
Abstract:The study of anti-protruding properties of dura and its substitutes is important to reconstnlction of skull defecfs. The parameters of anti-protruding properties of dura and its substitutes are introduced on the basis of constant creep solution of the dural deflection under the constant intracranial pressure. Dura and its Substitutes are arranged in order to the parameters: fresh human dura is the best anti-protruding material, lyophilized human dura is the best substitute, and artificial membrane of bovine cardiac valve, silicone rubber and terylene are unsuitable for use as anti-protruding material. The measurements showed that dura is isotropic approximately, which temporalis myofascia and pericranium are anisotropic.
Keywords:Dural Reconstruction, lyophilized dura, dura substitutes, anti-protruding properties.参考文献:
[1]吴彦桥,任光.颅底肿瘤术后缺损的重建和修复材料研究进展.中国耳鼻咽喉颅底外科杂志1995;1:56.