THE BIOMECHANICAL PRINCIPLE OF COMPRESSION STEEL PLATE OF GEAR CONTACT HALF CYCLE AND CHANNEL TYPE FOR HUMERUS FRACTURE
zhang Shu Hui,Li Ang,Huang Zong Qiang(Department o[ orthopaedic surgery, the Second Affiliated Hospital of He nan Medical University 450003)
Abstract:objective: Through the development of traditional steel plate according to the biomechanic principle of fracture stabihzation, author developed a new kind of internal fixture-compress steel plate of gear contact half cycle and channel type(GCC)and then made a biomechanic test on it in order to provide experimental bases for safety clinical practice. METHOD: Nine fresh adult moist cadaveric humerus specimens used in the experiment were divided into three groups at random: normal bone group(N). test group(GCC)and general compress plate group(GCP), the biomechanic tests were conducted respectively. Results: The effect of fixation strength, stiffness, stabihty and ultimate compress strength by GCC is better than that of general compress plate(GCP). Conclusions: Being used in long bone fracture, the internal fixture of GCC is firm, dependable and GCC’S biomechanic performance is superior. This instrument of reasonable structure is safe, simple and practical and it can be widely used in clinieal practice.